Sunbeds
Direct's transformers are specifically designed
to serve the voltage transformation needs
of tanning salons of all sizes. Most tanning
beds require voltages between 220V and 235V
for proper operation, while standard North
American line voltages are usually 208V
or 240V. We provide a simple and economical
solution for the installation of both single
and three-phase beds.
|

Order
Now |
| Buck
Booster: FAQ's |
|
1. Why do I need a buck booster?
- Some
tanning units, particularly those that
operate on a choke start system, require
a buck booster. Choke start systems are
very voltage dependent. When properly
installed and wired, a buck booster will
either "buck" (decrease) or
"boost" (increase) your incoming
voltage so it will be at a level that
the bed was designed to operate on.
- For
example, if your existing actual voltage
is reading 246, and you have a bed that
calls for 230 volts, you should install
a buck booster to bring your voltage down.
- The
buck boosters can be wired to either increase
or decrease your voltage 16 or 32 volts
or 12 or 24 volts.
- If
you are unsure what your bed's ideal operating
voltage is, please contact us (847) 636-7000
2.
How do I determine what size buck booster
I need?
- Buck
boosters are available in several different
sizes, the most commonly used in the tanning
industry are 20 amp, 30 amp, 40-50 amp,
and 60-80 amp.
- The
size you needs depends on the running
amperage of your tanning unit. As a rule
of thumb, most 24 through 28 lamp units
use a 20 amp. Most 30 amp units and higher
use a 30 amp. Larger units such as 42
lamps+ units vary between the 30amps and
40-50 amp. Many stand up units and high
pressure units require a 60-80 amp buck
booster.
3.
If I change locations, do I have to buy
new buck boosters?
-
As long as the buck booster is in proper
working order, you should not have to
purchase new buck boosters. They can be
rewired for your new voltage needs by
an electrician.
4.
How many buck boosters do I need for each
tanning bed?
- Most
tanning units require one buck booster
per unit.
- If
your location is on a three phase electrical
system, you will probably require more
than one buck booster per unit, particularly
with larger units.
- For
example, if you are on three phase "Delta"
208V, you may require 2 buck boosters
per unit. With three phase "Y"
208V, you may require 3 buck booster.
- Please
contact us to determine exactly how many
buck boosters you will need.